Specifications
Technical Data
Description
Power supply
6 to 36V DC.
Interfaces
CAN Bus
PC interfaces
None
Enclosure
Dimension (L115xH46xW105)
Weight 450g/IP65/ABS
Environmental
-40°C to +85°C Humidity max 90%
Output voltages
5V and 24V (Max current drawn 80 mA combined)
Analog Inputs
Number of channels
8 Bipolar differential inputs
Accuracy
±0.0015%
Software switchable range
±80V, ±40V, ±20V, ±10V
Resolution (ADC)
16 Bit
Max Sampling Rate
(10 KHz) 2 channel, (5 KHz) 2 channel, (2 KHz) 4 channel, (1 KHz) 8 channel (Thermocouple and Digital Data will be turned off when rates above 1 ms are used for ADC channels.)
Input impedance
> 4 M Ohm
Max input voltage
±75 Analog Ground, ±50 V Analog inputs
Thermocouple Inputs
Number of channels
8 J/K/T-type inputs
Accuracy
±1°C accuracy
Measurement Range
Measurement: -200 °C to 1250 °C
Max Sampling Rate
10 Hz (all 8 channels)
Maximum input voltage
±3.3 V
Digital Input / Output
Number of channels
×4 unipolar single-ended hardware configured as inputs or outputs
Input switching thresholds
Low < 1.5V
High > 2.0V (up to 12V)
Input leakage current
< 10nA
Output states
(Optional) Open collector - 510 Ohm
Output drive capability (OK): Collector-emitter voltage
45V max
Collector current (DC)
10mA max
Saturation voltage (OK on)
< 0.15V
Equivalent on-resistance
< 510Ohm
Leakage current at OK off
< 5uA
Min-max applied voltage
Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA
PWM
3 digital input frequency measurements up to 100kHz or pulse measurements. (min 100 Nano sec) (between pulses 10 microseconds)
Last updated