Specifications
Technical Data | Description |
Power supply | 6 to 36V DC. |
Interfaces | CAN Bus |
PC interfaces | None |
Enclosure | Dimension (L115xH46xW105) Weight 450g/IP65/ABS |
Environmental | -40°C to +85°C Humidity max 90% |
Output voltages | 5V and 24V (Max current drawn 80 mA combined) |
| Analog Inputs |
Number of channels | 8 Bipolar differential inputs |
Accuracy | ±0.0015% |
Software switchable range | ±80V, ±40V, ±20V, ±10V |
Resolution (ADC) | 16 Bit |
Max Sampling Rate | (10 KHz) 2 channel, (5 KHz) 2 channel, (2 KHz) 4 channel, (1 KHz) 8 channel (Thermocouple and Digital Data will be turned off when rates above 1 ms are used for ADC channels.) |
Input impedance | > 4 M Ohm |
Max input voltage | ±75 Analog Ground, ±50 V Analog inputs |
| Thermocouple Inputs |
Number of channels | 8 J/K/T-type inputs |
Accuracy | ±1°C accuracy |
Measurement Range | Measurement: -200 °C to 1250 °C |
Max Sampling Rate | 10 Hz (all 8 channels) |
Maximum input voltage | ±3.3 V |
| Digital Input / Output |
Number of channels | ×4 unipolar single-ended hardware configured as inputs or outputs |
Input switching thresholds | Low < 1.5V |
High > 2.0V (up to 12V) | |
Input leakage current | < 10nA |
Output states | (Optional) Open collector - 510 Ohm |
Output drive capability (OK): Collector-emitter voltage | 45V max |
Collector current (DC) | 10mA max |
Saturation voltage (OK on) | < 0.15V |
Equivalent on-resistance | < 510Ohm |
Leakage current at OK off | < 5uA |
Min-max applied voltage | Digital input -8V to +12V; Digital output 0V to +40V power supply, which limits the current to 10mA |
PWM | 3 digital input frequency measurements up to 100kHz or pulse measurements. (min 100 Nano sec) (between pulses 10 microseconds) |