Getting Started

Introduction

The K-TC 2.0 is Influx's upgraded version of the older K-TC modules. Like the previous modules, these are stackable instrumentation devices compatible with Influx's entire range of data loggers. These can also be integrated with any device configured via DBC files, other logger systems, or output signals on CAN for the Rebel Dash display.

The K-TC 2.0 is an ideal solution for applications that require a large number of thermocouple inputs. The K-TC 2.0's accurate sensor data is transmitted periodically on the CAN bus, enabling multiple devices to be connected. In addition, The temperature data is simultaneously logged in the inbuilt micro SD card (8GB), the K-TC 2.0 CAN bus settings, calibration and sampling rates are all easily configurable, and these settings are stored within the K-TC 2.0 even when the device is not powered.

K-TC8
K-TC16
K-TC32

Technical Specifications:

Technical Data
Description

Power supply

4.5 to 31V DC (isolated)

Power consumption

K-TC8 / K-TC16 / K-TC32

Normal operation

120mA at 12V / 140mA at 12V / 200mA at 12V

Power down standby mode

24mA at 12V / 25mA at 12V / 30mA at 12V

Configuration

Via CAN bus with K-Cal for calibration. Via USB with TC Logger SW for logging configurations stored in the device

Interfaces (Isolated)

CAN bus (max 1000 kbps) and USB 2.0

Storage

8 GB eMMc

PC Interfaces

USB2.0 Type B (isolated)

Enclosure

Dimension (LxHxW): 115x56(K-TC8) / 79(K-TC16) / 149(K-TC32) x 105mm

Weight 450g(K-TC8), 570g(K-TC16), 900g(K-TC32)

IP 65 (With all thermocouples plugged in)

ABS/Aluminium Allow* (depending upon the stock availability)

Environmental

-40°C to +85°C

Humidity max 90%

Thermocouple Inputs

K, J, T-type

Accuracy ± 1°C

Measurement: -200 °C to 1250 °C

Connection type

Thermocouples: mini K, J ,T-Type (galvanically isolated)

Thermocouple Inputs

Number of channels

K-TC8: 8 channels, K-TC16: 16 channels, K-TC32: 32 channels (group of 8 thermocouples - each galvanically isolated)

Channel Input Types

K, J, T

Measurement Range

(-)200°C to (+)1200°C

Max Sampling Rate

20 Hz per channel

Max applied voltage

± 3.3 V

Peak Galvanic Isolation Voltage

(from all other modules and power supplies)

Three-wire CAN Bus

780 V

Four-wire USB Bus

840 V

Two-wire power module

560V