Pinout Details: ReXgen Air
There are two connectors, a 24-pin Molex Mini50 connector and a male 25-pin Standard D Type connector.
Last updated
There are two connectors, a 24-pin Molex Mini50 connector and a male 25-pin Standard D Type connector.
Last updated
PIN No
PIN Function
Optional
Pin 1
RelayOut0
Relay Driver
Pin 2
DigIn0
Pin 3
AnalogGnd
Pin 4
Adc1
Pin 5
Wake-UP/Clamp-15
Pin 6
CAN0-L
Pin 7
CAN1-L
Pin 8
CAN2-L
Additional CAN FD 3rd bus
Pin 9
CAN3-L
Additional CAN FD 4th bus
Pin 10
usbDP_conn
Request when ordering
Pin 11
4.5Vout
Pin 12
DIgIn1
Pin 13
Adc0
Pin 14
Erase#
Pin 15
LIN
Pin 16
GND
Pin 17
PowerGND
Pin 18
5V to 27V
Pin 19
CAN0-H
Pin 20
CAN1-H
Pin 21
CAN2-H
Additional CAN FD 3rd bus
Pin 22
CAN3-H
Additional CAN FD 4th bus
Pin 23
usb5V
Request when ordering
Pin 24
usbDM_conn
Request when ordering
Pin No
Pin Function
Pin 3
CAN Bus 3 Low Signal (Available only on 4x CAN Model)
Pin 4
Analog Input 1 - do not apply voltages outside of the -10 to +10V range
Pin 5
Wake-Up pin to wake logger from sleep mode
Pin 6
CAN Bus 1 Low Signal
Pin 7
CAN Bus 0 Low Signal
Pin 9
5V to 27V Supply Voltage
Pin 10
+4.5V Instrumentation Supply Voltage, ensure that current draw is not more than 100mA
Pin 11
Erase PIN
Pin 12
Digital Input 0 - When used as an input, do not apply voltages outside the 0 to +12V range.
More information on the use of this pin can be found in Annexure
Pin 13
CAN Bus 2 Low Signal (Available only on 4x CAN Model)
Pin 15
LIN 0 Signal
Pin 16
CAN Bus 3 High Signal (Available only on 4x CAN Model)
Pin 17
Analog Input 0 - do not apply voltages outside of the -10 to +10V range
Pin 18
Analog Ground
Pin 19
CAN Bus 1 High Signal
Pin 20
CAN Bus 0 High Signal
Pin 21
Ground
Pin 22
Power Ground
Pin 23
Relay Out (Optional Feature)
Pin 24
Digital Input 1 - When used as input, do not apply voltages outside the 0 to +12V range
More information on the use of this pin can be found in Annexure
PIN 25
CAN Bus 2 High Signal (Available only on 4x CAN Model)
To set up a USB via the Molex connector, please specify this requirement when ordering, or the device must be sent back to Influx (as this requires some hardware modification).
The connector must be tightened securely to connect properly, ensuring reliable operation.
Each end of the CAN bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.
Do not short-circuit any pins.
The maximum safe applied voltage for analog and digital I/P is ±28 V
Do not use the logger's USB port for data logging, as it may damage the USB port, which won't be covered under warranty.