LogoLogo
Home
  • 🏠Home
  • ReXgen Series
  • Standard Operating Procedure - ReXgen
  • Pinout Details: ReXgen 1
  • Pinout Details: ReXgen 2/IMU
  • Pinout Details: ReXgen Air
  • ReXgen 1
    • Start-up Guide: ReXgen 1
    • ReXgen 1- Product Manual
      • Overview of the Device
        • Product Dimensions and Elements
        • Technical Specifications
        • Electrical Data
        • Intended Use
        • Liability & Warranty
        • Device Kit
        • Service & Support
      • Hardware, Functions, and Accessories
        • Hardware
          • Enclosure
          • Pinout
        • Functions
          • Recording CAN Data
          • Functioning as a PASS-THRU device using J2534:
        • Accessories
      • Getting Started
        • Connecting the Device
        • Software Installation
        • Driver Installation
        • ReXgen1 as a J2534 tool
        • Firmware Update
      • Annexures
  • ReXgen 2/IMU Product Manual
    • Start-up Guide: ReXgen 2/IMU
    • ReXgen 2/IMU- Product Manual
      • Overview of the Device
        • Product Dimensions and Elements
        • Technical Specifications
        • Electrical Data
        • Intended Use
        • Liability & Warranty
        • Conformity
        • Device Kit
        • Service & Support
      • Hardware & Functionality
        • Hardware
          • Enclosure & Cables
          • PinOut Details
          • GNSS Antenna Connector
          • Indicator Elements – LED'S
          • Accessories
        • Functionality
          • Recording CAN/CAN FD Data
          • Recording LIN Data
          • Recording GNSS Data
          • Recording Accelerometer & Gyroscope Data
          • Digital & Analog Input Functions
          • Functioning as a PASS-THRU device using J2534:
      • Getting Started
        • Software Installation
        • Driver Installation
        • ReXgen2 as a J2534 tool
        • Firmware Update
      • Annexures
        • Digital Input Functions
        • Certifications
          • FCC
          • CE
          • ROHS
        • CAN Overview
  • REXGEN AIR PRODUCT MANUAL
    • Start-up Guide: ReXgen Air
    • ReXgen AIR- Product Manual
      • Overview of the Device
        • Product Dimensions and Elements
        • Technical Specifications
        • Electrical Data
        • Intended Use
        • Liability & Warranty
        • Device Kit
        • Service & Support
      • Hardware & Functionality
        • Hardware
          • Enclosure
          • ReXgen Air: PinOut Details
          • GNSS Antenna Connector
          • Indicator Elements – LEDS
          • Accessories
        • Functionality
          • Recording CAN Data
          • Recording LIN Data
          • Recording GNSS Data
            • GNSS Positioning
            • Dead Reckoning
              • IMU Orientation
            • Geofencing
          • Recording Accelerometer & Gyroscope Data
          • Digital & Analog Input Functions
      • Getting Started
        • Software Installation
        • Driver Installation
        • Firmware Update
      • Annexures
        • Digital Input Function
        • The Wake-Up Pin
        • CAN Overview
  • ReXgen Series Usage Guides
    • ReXgen as Pass-Thru
      • The applications which support J2534 should show installed devices.
        • Module Analyser
        • K-Cal
      • SavvyCAN
    • SavvyCAN with ReXgen
      • Adding DBC File to SavvyCAN and viewing live data
      • Sending custom CAN messages
    • Log OBD2 Mode 1 with ReXgen
  • ReXgen Air - Cloud usage guides
    • Cloud Usage Guides For ReXgen Air Device
      • Quick Start Guide For AWS S3- ReXgen Air
        • AWS Bucket Creation
        • How to Create an Access key and secret key to access the S3 Bucket?
        • Configuring ReXgen AIR
          • Mobile Settings
          • AWS Settings
            • Steps to add new AWS settings using ReXdesk
            • Steps to enable AWS configuration in the ReXgen logger
          • Uploading AWS and Mobile settings
      • Deploying Lambda Function To AWS
        • For Beginners
        • For Advanced Users
        • Adding S3 Trigger for Lambda
        • Configuring conversion settings
        • Adding the DBC file for conversion
      • Running ReXcloud Docker Image on a local PC
      • Self-hosting with ReXgen Air - MinIO
        • Step 1 - Allow traffic on port 9000
        • Step 2 - Access MinIO console
        • Step 3 - Create Bucket
        • Step 4 - Create Access and Security Key
        • Step 5 - Adding S3 Settings
        • Step 6 - Load Configuration
      • Setting Grafana Dashboard with Parquet
        • Adding S3 Trigger for Lambda
        • Configuring conversion settings
        • Configuring AWS Glue settings
          • Option 1 - To add data to the database, based on time
        • Setting a Grafana Dashboard using the Athena plugin
      • Setting up FileZilla FTPS
        • Adding users and selecting the directory for saving the file.
        • Configuring ReXgen AIR
          • Mobile Settings
          • FTP Settings
          • Uploading FTP and Mobile settings
Powered by GitBook
On this page
  • Software Installation
  • Driver Installation
  • Software Update
  • Firmware Update
  • Configuring Steps to Log CAN trace data in ReXgen and Extract it to BLF/ASC Formats.
Export as PDF

Standard Operating Procedure - ReXgen

PreviousReXgen SeriesNextPinout Details: ReXgen 1

Last updated 8 months ago

Software Installation

Before proceeding with the installation, please ensure you have acquired administrative privileges. Make sure you have installed the Microsoft Visual C++ Redistributable (x86).

You can download it from the following link:

Dotnet runtime 4.7.2 is required

The latest release of ReXdesk software can be directly downloaded from

To begin the installation of the ReXdesk software, open the installer by running the set-up file

Driver Installation

To install the ReXgen driver, run the .exe file in this location:

C:\Program Files (x86) \Influx Technology\ReXdesk\Drivers.

The .exe file can also be found under Influx Technology's start menu. Run the ReXgenInstaller.exe file.

Software Update

Uninstall any previous version of ReXdesk before installing the new version.

Updated releases of ReXdesk software can be directly downloaded from

To begin the installation of the ReXdesk software, open the installer by running the set-up file

Firmware Update

The firmware file is located in (C:\Program Files (x86) \Influx Technology\ReXdesk\Firmware)

The "Reflash" option in the device menu allows the user to update the data logger's firmware.

  • Do not disconnect the logger until the logger LED stops flashing.

  • The logger will automatically reconnect to the software after re-flashing.

  • Please ensure that the internal storage is formatted after re-flashing the logger.

  • Update ReXgen with the new configuration once updates are made.

Notes:

  • Do not roll back from the current firmware version to an older version; the data recorded will be lost.

Configuring Steps to Log CAN trace data in ReXgen and Extract it to BLF/ASC Formats.

Drag and drop "log all "from tools to the required CAN bus (CAN0/1/2/3) or LIN Bus:

To set CAN speed, click on the Bus icon.

Specify the required information in the following window.

Set the max log size/time for log files.

Click on "Storage" and choose max log time & size.

Interface ReXgen and click "Run" to update the configuration.

Check the LED indications on Rexgen – LED lights will be bold for the configured CAN bus.

Once Rexgen is interfaced with CAN, LED lights start blinking, indicating it has started logging.

Also, verify that a new log file is created for updated internal storage configuration with proper start and end times.

Otherwise, update the time by using the "set time" option.

After logging, select the logged file from "Internal storage" and click "Download."

Click the "Advanced "option.

Select "output format" and "output location", and click process.

Notes:

Please refer to the ReXgen user manual for further assistance.

ReXgen Manual can be accessed from the "Help" menu in ReXdesk.

https://aka.ms/vs/17/release/vc_redist.x86.exe
https://dotnet.microsoft.com/en-us/download/dotnet-framework/thank-you/net47-web-installer
https://docs.influxtechnology.com/software-links/software-links/rexdesk-software-links
https://docs.influxtechnology.com/software-links/software-links/rexdesk-software-links
429KB
Rexgen SOP_2024.pdf
pdf
Page cover image