LogoLogo
Home
  • 🏠Home
  • ReXgen Series
  • Standard Operating Procedure - ReXgen
  • Pinout Details: ReXgen 1
  • Pinout Details: ReXgen 2/IMU
  • Pinout Details: ReXgen Air
  • Pinout Details: ReXgen Pro
  • Pinout Details: ReXgen OEM
  • ReXgen 1
    • Start-up Guide: ReXgen 1
    • ReXgen 1- Product Manual
      • Overview of the Device
        • Product Dimensions and Elements
        • Technical Specifications
        • Electrical Data
        • Intended Use
        • Liability & Warranty
        • Device Kit
        • Service & Support
      • Hardware, Functions, and Accessories
        • Hardware
          • Enclosure
          • Pinout
        • Functions
          • Recording CAN Data
          • Functioning as a PASS-THRU device using J2534:
        • Accessories
      • Getting Started
        • Connecting the Device
        • Software Installation
        • Driver Installation
        • ReXgen1 as a J2534 tool
        • Firmware Update
      • Annexures
  • ReXgen 2/IMU Product Manual
    • Start-up Guide: ReXgen 2/IMU
    • ReXgen 2/IMU- Product Manual
      • Overview of the Device
        • Product Dimensions and Elements
        • Technical Specifications
        • Electrical Data
        • Intended Use
        • Liability & Warranty
        • Conformity
        • Device Kit
        • Service & Support
      • Hardware & Functionality
        • Hardware
          • Enclosure & Cables
          • PinOut Details
          • GNSS Antenna Connector
          • Indicator Elements – LED'S
          • Accessories
        • Functionality
          • Recording CAN/CAN FD Data
          • Recording LIN Data
          • Recording GNSS Data
          • Recording Accelerometer & Gyroscope Data
          • Digital & Analog Input Functions
          • Functioning as a PASS-THRU device using J2534:
      • Getting Started
        • Software Installation
        • Driver Installation
        • ReXgen2 as a J2534 tool
        • Firmware Update
      • Annexures
        • Digital Input Functions
        • Certifications
          • FCC
          • CE
          • ROHS
        • CAN Overview
  • REXGEN AIR PRODUCT MANUAL
    • Start-up Guide: ReXgen Air
    • ReXgen AIR- Product Manual
      • Overview of the Device
        • Product Dimensions and Elements
        • Technical Specifications
        • Electrical Data
        • Intended Use
        • Liability & Warranty
        • Device Kit
        • Service & Support
      • Hardware & Functionality
        • Hardware
          • Enclosure
          • ReXgen Air: PinOut Details
          • Antenna Connector
          • Indicator Elements – LEDS
          • Accessories
        • Functionality
          • Recording CAN Data
          • Recording LIN Data
          • Recording GNSS Data
            • GNSS Positioning
            • Dead Reckoning
              • IMU Orientation
            • Geofencing
          • Recording Accelerometer & Gyroscope Data
          • Digital & Analog Input Functions
      • Getting Started
        • Software Installation
        • Driver Installation
        • Firmware Update
      • Annexures
        • Digital Input Function
        • The Wake-Up Pin
        • CAN Overview
  • ReXgen Pro Product Manual
    • Start-up Guide: ReXgen Pro
    • ReXgen Pro- Product Manual
      • Overview of the Device
        • Product Dimensions and Elements
        • Technical Specifications
        • Electrical Data
        • Intended Use
        • Libility & Warranty
        • Device Kit
        • Service & Support
      • Hardware and Functionality
        • Hardware
          • SIM Card Insertion (for devices with non-soldered SIM cards)
          • Enclosure
          • ReXgen Pro: PinOut Details
          • Antenna Connector
          • Accessories
        • Functionality
          • Recording CAN/CAN FD Data
          • Recording LIN Data
          • Recording GNSS Data
          • IMU Orientation
          • Recording Acclerometer & Gyroscope Data
          • Digital & Analog Input Functions
      • Getting Started
        • Software Installation
        • Driver Installation
        • Configuring Wi-Fi setting to Start up a Pro Device
        • Firmware Update
      • Annexures
        • Digital Input Function
        • The Wake-Up Pin
        • CAN Overview
  • ReXgen OEM Product Manual
    • ReXgen OEM - Quick Start Guide
      • Technical Specification
      • Pinout Details: ReXgen OEM
        • JAE Compact Automotive 34-pin Connector
        • JAE Compact automotive 34-pin Connector to D Sub 25 connector
        • RJ45 (Ethernet connector)
        • 2- Way Multiconnect Cable
        • 5 - Way Multiconnect Cable
  • ReXgen Series Usage Guides
    • ReXgen as Pass-Thru
      • The applications which support J2534 should show installed devices.
        • Module Analyser
        • K-Cal
      • SavvyCAN
    • SavvyCAN with ReXgen
      • Adding DBC File to SavvyCAN and viewing live data
      • Sending custom CAN messages
    • Log OBD2 Mode 1 with ReXgen
  • ReXgen Air - Cloud usage guides
    • Cloud Usage Guides For ReXgen Air Device
      • Quick Start Guide For AWS S3- ReXgen Air
        • AWS Bucket Creation
        • How to Create an Access key and secret key to access the S3 Bucket?
        • Configuring ReXgen AIR
          • Mobile Settings
          • AWS Settings
            • Steps to add new AWS settings using ReXdesk
            • Steps to enable AWS configuration in the ReXgen logger
          • Uploading AWS and Mobile settings
      • Deploying Lambda Function To AWS
        • For Beginners
        • For Advanced Users
        • Adding S3 Trigger for Lambda
        • Configuring conversion settings
        • Adding the DBC file for conversion
      • Running ReXcloud Docker Image on a local PC
      • Self-hosting with ReXgen Air - MinIO
        • Step 1 - Allow traffic on port 9000
        • Step 2 - Access MinIO console
        • Step 3 - Create Bucket
        • Step 4 - Create Access and Security Key
        • Step 5 - Adding S3 Settings
        • Step 6 - Load Configuration
      • Setting Grafana Dashboard with Parquet
        • Adding S3 Trigger for Lambda
        • Configuring conversion settings
        • Configuring AWS Glue settings
          • Option 1 - To add data to the database, based on time
        • Setting a Grafana Dashboard using the Athena plugin
      • Setting up FileZilla FTPS
        • Adding users and selecting the directory for saving the file.
        • Configuring ReXgen AIR
          • Mobile Settings
          • FTP Settings
          • Uploading FTP and Mobile settings
Powered by GitBook
On this page
Export as PDF
  1. ReXgen 2/IMU Product Manual
  2. ReXgen 2/IMU- Product Manual

Overview of the Device

This chapter overviews the device, its operating elements and functions, and its intended use.

PreviousReXgen 2/IMU- Product ManualNextProduct Dimensions and Elements

Last updated 4 months ago

Along with the free, user-friendly configuration software, the standalone ReXgen2 logger comes with the following advantages:

  • The extreme level of compactness – pocket size

  • Tolerable to harsh environments with an IP65 rating

  • Secure data storage with an internal eMMC

  • Supports CAN, CAN FD & LIN buses.

  • Functions as an interface device and supports J2534 (Pass-thru).

  • Supports live CAN trace monitoring, RAW CAN signals, and SAE J1939.

  • Sleep modes with wake up on CAN, wake on alarm & wake up on signal

  • Most advanced trigger & filter conditions

  • In-built gyroscope & accelerometer modules

  • 2 x digital & 2 analog inputs

  • Up to 18 Hz rate GNSS module

  • Micro USB 2.0 PC interface

  • Internal temperature sensor

  • CAN error logging

Model

eMMC Storage

CAN/CAN FD

Analog I/P

Accelerometer & Gyroscope

GNSS

INF2110.01

8 GB

2

2

No

No

INF2110.02

16 GB

2

2

No

No

INF2112.02

16 GB

2

2

Yes

Yes

INF2112.03

32 GB

2

2

Yes

Yes

Available Models
Technical Specifications