Start-up Guide: ReXgen Air

To download the ReXdesk software

  1. Visit Influx Technology.com >> Support >> ReXgen Series >> Software links >> ReXdesk Download

  2. Windows Search >> ReXgen Drivers >> Select and Install

WARNING:

Notes:

  • CAN Bus and USB Isolators can be purchased separately.

  • Do not use the logger's USB port for data logging, as it may damage the USB port, which won't be covered under warranty.

SIM Card Insertion

To insert the SIM card in a ReXgen Air device, open the lid on the SIM slot correctly and carefully. Mishandling the SIM slot lid may damage the device and the SIM card inside.

Ensure the SIM is inserted, as shown, in the images above (chip facing down).

24-pin Molex Mini50 Connector Details

PIN Number
PIN Function
Optional

PIN 1

RelayOut0

Relay Driver

PIN 2

DigIn0

PIN 3

AnalogGnd

PIN 4

Adc1

PIN 5

Wake-UP/Clamp-15

PIN 6

CAN0-L

PIN 7

CAN1-L

PIN 8

CAN2-L

Additional CAN FD 3rd bus

PIN 9

CAN3-L

Additional CAN FD 4th bus

PIN 10

usbDP_conn

Request when ordering

PIN 11

4.5Vout

PIN 12

DIgIn1

PIN 13

Adc0

PIN 14

Erase#

PIN 15

LIN

PIN 16

GND

PIN 17

PowerGND

PIN 18

5V to 27V

PIN 19

CAN0-H

PIN 20

CAN1-H

PIN 21

CAN2-H

Additional CAN FD 3rd bus

PIN 22

CAN3-H

Additional CAN FD 4th bus

PIN 23

usb5V

Request when ordering

PIN 24

usbDM_conn

Request when ordering

Male 25-pin Standard D Type connector (Mini 50 to D Sub 25 cable can be purchased separately)

Notes:

  • The connector must be tightened securely to connect properly, ensuring reliable operation.

  • Each end of the CAN bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.

  • Do not short-circuit any pins.

  • Do not use the logger's USB port for data logging, as it may damage the USB port, which won't be covered under warranty.

To update the firmware

Open ReXdesk, connect the logger and click the ‘Reflash’ option under the Device tab.

Reflash – Select the required firmware to update the logger.

Notes:

  • Do not disconnect the logger until the logger LED stops flashing. The logger will automatically re-connect to the software after reflashing.

  • Please ensure that the internal storage is formatted after reflashing the logger.

LED Indicators

The 4 LEDs on the ReXgen Air indicate CAN/CAN FD logging activity.

LED

Indication when BOLD

Indication when BLINKING

LED 1

Configured for CAN 0 Log

Active logging on CAN 0

LED 2

Configured for CAN 1 Log

Active logging on CAN 1

LED 3

Configured for GPS Log

Active logging

LED 4

NA

Fast Blinking: Attempting to connect.

Slow Blinking: Connected

To set the time

Open ReXdesk, connect the logger and click ‘Set Time’ on the top taskbar.

To synchronise the logger’s time with your PC, select ‘Synchronise with PC.

Or

To manually set the logger’s time, select ‘Set Custom Date Time’.

Click ‘Set Time” to save.

To start logging

Open ReXdesk, connect the logger, double-click, or drag and drop the ‘Log All’ icon into the configuration window.

Click the ‘Run’ icon on the top taskbar and save the project.

Once the Configuration is uploaded successfully, click OK.

To open a data log from internal storage

Click the ‘Internal Storage’ icon on the top taskbar and select the file you wish to open.

Click on the ‘Download’ tab and select the required format for download.

Notes:

  • Always ensure the device is installed, connected, and commissioned by a qualified professional.

  • The device must only be repaired by the manufacturer.

Refer to ReXgen Air's Product Manual for more details.