Start-up Guide: ReXgen Air
Last updated
Last updated
Visit Influx Technology.com >> Support >> ReXgen Series >> >> ReXdesk Download
Windows Search >> ReXgen Drivers >> Select and Install
To insert the SIM card in a ReXgen Air device, open the lid on the SIM slot correctly and carefully. Mishandling the SIM slot lid may damage the device and the SIM card inside.
Pin No | Pin Function |
Pin 3 | CAN Bus 3 Low Signal (Available only on 4x CAN Model) |
Pin 4 | Analog Input 1 - do not apply voltages outside of the -10 to +10V range |
Pin 5 | Wake-Up pin to wake logger from sleep mode |
Pin 6 | CAN Bus 1 Low Signal |
Pin 7 | CAN Bus 0 Low Signal |
Pin 9 | 5V to 27V Supply Voltage |
Pin 10 | +4.5V Instrumentation Supply Voltage, ensure that the current drawn is not more than 100mA |
Pin 11 | Erase PIN |
Pin 12 | Digital Input 0 - Do not apply voltages outside the 0 to +12V range when used as an input. More information on the use of this pin can be found in Annexure 2 |
Pin 13 | CAN Bus 2 Low Signal (Available only on 4x CAN Model) |
Pin 15 | LIN 0 Signal |
Pin 16 | CAN Bus 3 High Signal (Available only on 4x CAN Model) |
Pin 17 | Analog Input 0 - do not apply voltages outside of the -10 to +10V range |
Pin 18 | Analog Ground |
Pin 19 | CAN Bus 1 High Signal |
Pin 20 | CAN Bus 0 High Signal |
Pin 21 | Ground |
Pin 22 | Power Ground |
Pin 23 | Relay Out (Optional Feature) |
Pin 24 | Digital Input 1 - When used as input, do not apply voltages outside the 0 to +12V range More information on the use of this pin can be found in Annexure 2 |
PIN 25 | CAN Bus 2 High Signal (Available only on 4x CAN Model) |
The connector must be tightened securely to connect properly, ensuring reliable operation.
Each end of the CAN bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.
Do not short-circuit any pins.
Do not use the logger's USB port for data logging, as it may damage the USB port, which won't be covered under warranty.
Open ReXdesk, connect the logger and click the ‘Reflash’ option under the Device tab.
Reflash – Select the required firmware to update the logger.
The 4 LEDs on the ReXgen Air indicate CAN/CAN FD logging activity.
LED | Indication when BOLD | Indication when BLINKING |
Configured for CAN 0 Log | Active logging on CAN 0 | |
Configured for CAN 1 Log | Active logging on CAN 1 | |
Configured for GPS Log | Active logging | |
NA | Fast Blinking: Attempting to connect. Slow Blinking: Connected |
Open ReXdesk, connect the logger and click ‘Set Time’ on the top taskbar.
To synchronise the logger’s time with your PC, select ‘Synchronise with PC.
Or
To manually set the logger’s time, select ‘Set Custom Date Time’.
Click ‘Set Time” to save.
Open ReXdesk, connect the logger, double-click, or drag and drop the ‘Log All’ icon into the configuration window.
Click the ‘Run’ icon on the top taskbar and save the project.
Once the Configuration is uploaded successfully, click OK.
Click the ‘Internal Storage’ icon on the top taskbar and select the file you wish to open.
Click on the ‘Download’ tab and select the required format for download.
LED 1
LED 2
LED 3
LED 4