Getting Started
CONNECTING THE DEVICE
Attention:
A qualified technician must install, connect, and commission the device.
Ensure the power supply is disconnected before connecting the device.
Only use components from the starter kits or the accessories supplied.
Do not use the logger's USB port for data logging purposes, as this may damage the port, which will not be covered under warranty.
POWER
A Molex connector provides the product's power supply. If the customer uses the multi-connect cables, DSub 9 or DSub 25 will be used, which applies to all the other connections.
CAN/CAN FD
ReXgen Air can be interfaced to the CAN/CAN FD bus, from which data will be logged using D-Sub 9 connector A or connector B. The CAN-high and CAN-low from the vehicle or machine terminals must match the CAN-high and CAN-low terminal of the ReXgen Air. ReXgen Air should be configured with the same baud rate as the device to which it is interfaced.
ANALOG AND DIGITAL INPUT
ReXgen Air supports 2x analogue inputs in the range of +/- 10 V. The two analogue inputs are interfaced to the ReXgen Air via a D-Sub 9 connector B. ReXgen Air also supports two digital inputs. The digital inputs are interfaced to the ReXgen Air via a D-Sub 9 connector A.
USB
You can connect the device to a PC via the communication gateway USB for configuration and test purposes. The device is supplied with a standard Micro USB cable. Please note that the USB is not isolated; an isolator can be purchased separately.
*x1 micro USB cable to be supplied with any quantity of ReXgen Air purchased.