Getting Started
CONNECTING THE DEVICE
Attention:
A qualified technician must install, connect, and commission the device.
Ensure the power supply is disconnected before connecting the device.
Only use components from the starter kits or the accessories supplied.
POWER
A JAE Compact Automotive 34-pin Connector is used to provide power supply to the device. If the customer uses the multi-connect cables, D-Sub-9 or D-Sub-25 will be used, which applies to all the other connections.
CAN/CAN FD
ReXgen Pro can be interfaced to the CAN/CAN FD bus, from which data will be logged using D-Sub 9 connector A or B. The CAN-high and CAN-low from the vehicle or machine terminals must match the CAN-high and CAN-low terminal of the ReXgen Pro. ReXgen Pro should be configured with the same baud rate as the device to which it is interfaced.
ANALOG AND DIGITAL INPUT
ReXgen Pro supports 3X analog inputs in the range of ±10 V. The two analog inputs are interfaced to the ReXgen Pro via a D-Sub 9 connector-B. ReXgen Pro also supports 2X digital inputs. The digital inputs are interfaced to the ReXgen Pro via a D-Sub 9 connector A.
Last updated