Getting Started

CONNECTING THE DEVICE

POWER

A JAE Compact Automotive 34-pin Connector is used to provide power supply to the device. If the customer uses the multi-connect cables, D-Sub-9 or D-Sub-25 will be used, which applies to all the other connections.

Notes:

  • The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.

  • Do not short-circuit any pins.

  • The maximum safe applied voltage is +28V

CAN/CAN FD

ReXgen Pro can be interfaced to the CAN/CAN FD bus, from which data will be logged using D-Sub 9 connector A or B. The CAN-high and CAN-low from the vehicle or machine terminals must match the CAN-high and CAN-low terminal of the ReXgen Pro. ReXgen Pro should be configured with the same baud rate as the device to which it is interfaced.

Notes:

  • Connector needs to be tightened properly to make a proper connection, ensuring reliable operation.

  • Each end of the CAN/CAN FD bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.

  • Do not short circuit any pins.

  • Maximum safe applied voltage is +28V.

  • CAN/CAN FD bus is not isolated by default; isolating device can be purchased separately.

ANALOG AND DIGITAL INPUT

ReXgen Pro supports 3X analog inputs in the range of ±10 V. The two analog inputs are interfaced to the ReXgen Pro via a D-Sub 9 connector-B. ReXgen Pro also supports 2X digital inputs. The digital inputs are interfaced to the ReXgen Pro via a D-Sub 9 connector A.

Notes:

  • The connector needs to be tightened properly to make a proper connection, ensuring reliable operation.

  • Do not short-circuit any pins.

  • The maximum safe applied voltage is +28V.

Last updated